Everyway4All EU300 Traction Table Features
- Everyway4All EU300 Traction-T 4-Section Traction Table includes:
– (Left) 60º + (Right) 60º Swivel Arm for various angle pulls
– 2 x Bolsters
– Extension Cord - 1 Motorized Actuator for Hi/Lo Adjustments
- 1 Motorized Actuator for Center Arching
- Twin oversized pillars for added stability
- Individual leveling foot on all 4 corners
- Retractable castors at both ends
- Twin Gas Struts for solid head section support
- Center Arching Mechanism for Motorized Lumbar Elevation facilitates any pulling traction force on the lumbar area with a slight upward lifting support (up to 26 Degree Rise) especially when the patient is lying in the prone position or facing down
- Gas-Driven Damper Strut:
– Used on the lower body (3rd and 4th) section of able top of the EU300 for auto-progressive returning during therapy
– This replaces the normally used “Recoil Spring” on other competing models
– This feature helps to smoothly and safely reduce the gap between the stationary and floating sections
– This means that the 3rd and 4th sections will always stay afloat and not be hitting the end of the frame during therapy
– At the end of a session, the Lower Body (3rd and 4th) section will gradually return to its original position as the traction force decreases - Weight: 116.2 kgs
- Note: Traction Unit (Head) shown in the picture is not included.
- User Manual
Instructions for Use
- Safety Instructions:
– Prior starting to use the table, it is important that you read and understand this manual.
– You may also consult this manual whenever you;re in doubt about using the table.
– This devise MUST BE USED under the supervision of a licensed practitioner.
– Use only the original accessories that is manufactured by Everyway Medical Inst. Co., Ltd. for the table.
– DO NOT USE the table in “Wet Rooms” – Hydrotherapy Rooms.
– Keep the table away from direct heat and/or fire. - Warnings:
– Please make certain that Electric Couches /Tables are not used in the presence of flammable gases such as anaesthetic agent.
– Do not sit on the edge of Head or Foot Section of a couch or table as possible damages to the (1) Gas Struts and/or (2) Gas Strut Handle Bar may occur. Standard Load of a couch or table is rated at which the loading weight is distributed evenly across the working surface but not on a specific area or side of table top.
– It is hazardous to exceed the rated maximum load of a couch or table.
– The operation Electric couch or table requires the Power Cord securely plugged-in to the wall utility power. When the Power Cord is unplugged, it does not operate unless the couch or table is equipped with a backup battery.
– Use only the original accessories that are manufactured by Everyway Medical Inst. Co., Ltd. for a table or couch.
– Children MUST be refrained from using any tables or couches by means of operating a hand or foot control nor Elevating Bars. - Cautions:
– Before allowing a patient to lay on the couch or table, please ensure that the Leveling Foot at each corner is LEVELED & RESTING on the floor securely after the castors are retracted. If not, please adjust the leveling foot accordingly to stabilize the table.
– Check any trapped power cords or cables underneath the couch or table while moving the table.
– Keep any persons; limbs away from all moving parts of a couch or table especially when the table is being moved from one place to another
– When applying electrotherapy to a patient, please keep his or her body away from any contacts with metal parts of the couch or table.
– Please familiarize yourself with the operation of all various controls of actuator and gas struts to avoid inadvertent actuation of table sections.
How does Everyway4all Traction Unit Works?
- The HOLD and REST time can be adjusted in real-time as well as the force
- Once set, press START and the new setting will take effect in the next coming cycle