Drive Fingertip Pulse Oximeter Features
- Operation of the product is simple and convenient
- Drive Fingertip Pulse Oximeter is small in volume, light in weight (total weight is about 50g, including batteries), and convenient to carry
- Power consumption of the product is low, and the two originally equipped AAA batteries can be operated continuously for 20 hours
- The product will automatically be powered off when no signal is in the product within 5 seconds
When to use Drive Pulse Oximeters?
Pulse oximeters are used regularly in all conditions that tend to affect blood oxygen saturation levels:
- COPD (Chronic Obstructive Pulmonary Disease)
- Lunge Cancer
- Pneumonia
- Heart Failure
- Anemia
- Asthma
- Heart Attack
What are normal SpO2 levels?
When a person’s activity level changes during the day, the values of the pulse oximeters, or oxygen saturation (the amount of oxygen transported by the blood in relation to its maximal capacity), may change. You must check your blood oxygen level four to five times per day and record the results with the things you did just before the check to calculate your average value.
- Most people consider a SpO2 of> or = 95% normal.
- Hypoxemia is indicated by a SpO2 of or = 92 percent (at sea level).
If the SpO2 falls below 92 percent, patients with acute respiratory illnesses like influenza or an asthma attack may require oxygen supplementation.
What to buy with Drive MQ3000 Fingertip Pulse Oximeter
- Reusable Face Shield
- Drive Oxygen Mask
What is the principle of the Drive Oximeter?
An experience formula of data process is established by taking use of Lambert Beer Law according to Spectrum Absorption Characteristics of Reductive Hemoglobin (11b) and Oxyhemoglobin (HbO,) in glow & near-infrared zones. The operation principle of the instrument is: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology so that two beams of different wavelengths of light can be focused onto a human nail tip through perspective clamp finger-type sensor. Then measured signal can be obtained by a photosensitive element, information acquired through which will be shown on screen through treatment in electronic circuits and microprocessors.
How to use Drive Fingertip Pulse Oximeter with LED Display?
How to install Drive Pulse Oximeter?
Battery
- Refer to Figure 3. and insert the two AAA-size batteries properly in the right direction.
- Replace the cover.
- Note: Please take care when you insert the batteries for the improper insertion may damage the device.
Mounting the lanyard
- Put the end of the lanyard through the hole.
- Put another end of the lanyard through the first one and then tighten it.